top of page

Flow Metering

Flow metering is used across all industries for consumption monitoring, leak monitoring and industrial process controls. It is used in buildings, factories and plants, vessels and offshore platforms and many more. Flow metering can be used for measurement of different types of fluid - water, gas, oil, chemicals etc. It is crucial for meters in industrial processes and consumption measurement for billing to be accurate and reliable.

AMI/AMR Smart Water Meter & Sensor
smart water meter.jpg

AMI/AMR Smart 

Water Meter

AMI/AMR Smart Water Meter
Smart water meters are mainly used for monitoring of consumption and billing in residential buildings, commercial buildings and industrial compounds.
 
These water meters have different principles of measurement - using multiple or single jet streams to rotate a turbine, measuring a fix volume of water through a high precision rotating chamber etc. The sensor which is mounted on the analog register of a water meter produces a low level "Pulse" or high level "M-bus" output during operation which goes to a building management system where the meter reading can be monitored. These outputs can also be converted to "Modbus" outputs.
1.png
2.png
3.png
4.png
5.png
6.png
7.png
8.png
9.png

Product Specifications available for AMI/AMR Smart Water Meter

Types available.png

Types of

AMI/AMR smart water meter available:

Multi-jet turbine

Woltmann

Ultrasonic
Positive displacement 

material available.png

Materials

available:

PPA

Cast iron

Bronze

DZR brass

Epoxy-coated

ductile iron

size available.png

Sizes

available:

DN15 to DN300

Max operating pressure.png

Max operating

pressure

available:

Up to 16 bar

Max operating temeperature.png

Max operating temperature

available:

Up to 130 °C

flow velocity.png

Nominal

flow rate

available:

1.5 to 2000 m3/hr

connection available.png

Connections

available:

Flanges PN10,

PN16

Threaded BSP

suitable media.png

Suitable media

types:

Clean water

Water with particles

output signal.png

Output signal

types

available:

Pulse

M-Bus

Modbus RTU

Radiofrequency LoRaWAN

battery.png

Sensor

Battery lifetime:

12 to 15 years

Data Logger
data logger.jpg

Data Logger

Data Logger
The data logger which is mounted on the analog register of a water meter produces a low level "Pulse" or high level ""M-bus"" output during operation which goes to a building management system where the meter reading can be monitored. These outputs can also be converted to "Modbus" outputs.
1.png

Product Specifications available for Data Logger

Types available.png

Types of data logger available:

M-Bus

device capacity.png

Device capacity:

Connect up to

250 M-Bus devices

power supply.png

Power supply required:

110 to 250VAC,

47 – 63 Hz

max power consumption.png

Max power consumption:

100W

braud rate.png

Baud rate:

300-9600 baud

data file.png

Data file type:

csv, xlsx, xml

though

USB flash drive,

FTP server,

email

terminals.png

Terminals available:

3 x terminals for M-Bus, plug-in terminals for

floating contacts

and relay outputs

oil meter.jpg
Oil Meter

Oil Meter

Oil Meter
Oil meters are used to measure heating fuel consumption by oil burners and propellant fuel consumption by motors and engines. During flow, a rotary piston mechanism (positive displacement) repeatedly counts the number of times the high precision measuring chamber rotates and discharges fluid, thus measuring the volumetric consumption.
1.png
2.png
3.png
4.png
5.png
6.png

Product Specifications available for Oil Meter

Types available.png

Types of oil meter available:

Positive displacement 

material available.png

Materials

available:

Brass

Ductile cast iron

size available.png

Sizes

available:

DN15 to DN50

Max operating pressure.png

Max operating

pressure available:

16 bar

25 bar

40 bar

Max operating temeperature.png

Max operating temperature

available:

130 °C

180 °C

flow velocity.png

Nominal flow

rate available:

0.4 to 20 m3/hr

connection available.png

Connections available:

Flanges PN16,

PN25, PN40

Threaded BSP

suitable media.png

Suitable media

types:

Heating fuel

Naphtha

Lubricating liquids (oils)

flow meter.jpg
Flow Meters

Flow Meter

Flow Meter
Flow meters are often used in industrial plants for monitoring and feedback of process controls. Different types of flow meters are used depending on application and media type.
​
Paddlewheel flow meters have a free rotating impeller with magnets, perpendicular to the flow. The magnetic blades rotate past the sensor during flow to generate a frequency proportional to the flow rate.
 
For magnetic flow meters, a magnetic field is generated perpendicular to the moving fluid. When a conductive fluid flows through the magnetic field, it causes a voltage signal to be sensed by the electrodes on the flow tube wall. The faster the fluid moves, more voltage will be generated.
 
Ultrasonic flow meters use soundwaves to measure fluid flow. During flow, the flow rate is measured by the difference between the frequency of the transmitted ultrasonic wave and frequency of the reflected wave.
1.png
2.png
3.png
4.png
5.png
6.png
7.png
8.png

Product Specifications available for Flow Meter

Types available.png

Types of

flow meter

available: Electromagnetic

Ultrasonic clamp-on Paddlewheel

Differential pressure

Variable area 

material available.png

Materials

available:

PVC / PP

PVDC

Brass

Stainless-

steel 316

Cast acrylic

Polysulfone

size available.png

Sizes

available:

DN6 to DN1350

Max operating pressure.png

Max operating

pressure

available:

10 to 16 bar

Max operating temeperature.png

Max operating temperature

available:

-30°C to 150 °C

flow velocity.png

Flow velocity

range:

0.03 to 12 m/s

connection available.png

Connections available:

Flanges PN16,

Flanges class 150,

300, JIS 10k

Threaded BSP, NPT

Socket weld

Clamp-on

True union

Spigot / Groove

suitable media.png

Suitable media

types:

Neutral,

solid free liquids Conductive fluids

Water

Clean water

Waste water

Corrosive fluids

Viscous fluids

output signal.png

Output signal

types available: Pulse

4-20mA

RS232

RS422

Modbus RTU

power supply.png

Power supply

required:

10 to 36 VDC

85 to

115,230 VAC

4 x 1.5 VDC

AA batteries

Lithium battery 

bottom of page